Braid screen control soft cable adopts multi-strand fine copper wire twisted soft conductor. The insulation and sheath are made of PVC. Common model examples are KVVRP and RVVP. The specific model parameters (such as number of cores, cross-sectional area, shielding coverage, etc.) need to be selected according to actual project needs and comply with GB/T 9330, JB 8734 and other standards.
Conductor: Multiple strands of fine copper wire twisted soft conductor
Insulation: PVC
Screen: Braided metal wire (such as tinned copper wire) outside the insulation layer
Sheath: PVC,Some models have flame retardant properties (such as ZR-KVVRP)
Rated voltages: 450/750V
Examples of common models :
KVVRP: Copper core PVC insulation + PVC sheath braided shielded control soft cable, rated voltage 300/500V, suitable for fixed or mobile laying.
RVVP: Soft conductor PVC insulation + PVC sheathed shielded cable, commonly used in low voltage control lines such as building intercoms and monitoring systems.
Notice:Specific model parameters (such as core number, cross-sectional area, shielding coverage, etc.) need to be selected according to actual project needs and comply with standards such as GB/T 9330 and JB 8734.
Cross-Sectional Area mm² | Thickness of Insulation mm | Thickness of Sheath mm | Overall Diameter mm | Approx Weight kg/km | Max.D.C resistance of at 20℃ Ω/km | |
min | max | |||||
2×0.5 | 0.8 | 1.2 | 7.4 | 9.3 | 74 | 39.0 |
2×1 | 0.6 | 1.2 | 8.0 | 10.0 | 94 | 19.5 |
2×2.5 | 0.8 | 1.2 | 10.1 | 12.6 | 159 | 7.98 |
3×0.5 | 0.6 | 1.2 | 7.8 | 9.7 | 85 | 39.0 |
3×0.75 | 0.6 | 1.2 | 8.1 | 10.1 | 99 | 26.0 |
3×1.5 | 0.7 | 1.2 | 9.3 | 11.6 | 142 | 13.3 |
4×0.5 | 0.6 | 1.2 | 8.3 | 10.4 | 100 | 39.0 |
4×1 | 0.8 | 1.2 | 9.0 | 11.2 | 131 | 19.5 |
4×1.5 | 0.7 | 1.2 | 10.0 | 12.5 | 171 | 13.3 |
... | ... | ... | ... | ... | ... | ... |
24×1 | 0.6 | 1.7 | 18.6 | 22.9 | 587 | 19.5 |
24×1.5 | 0.7 | 1.7 | 21.2 | 26.0 | 799 | 13.3 |
24×2.5 | 0.8 | 1.7 | 25.2 | 30.8 | 1193 | 7.98 |
Typical application areas:
Industrial control: Connect PLC, sensors, inverters and other equipment for automated production line control loops in metallurgy, petrochemical and other industries.
Building intelligence: Fire alarm system, security monitoring, elevator control and other weak current signal transmissions that require shielding interference.
Instruments: Laboratory equipment, medical instruments and other scenes with high signal accuracy requirements to prevent data distortion caused by electromagnetic interference.